How we use electrostatic interactions to remove aggregates, leached Protein A, HCPs, and DNA after viral inactivation.
Welcome back to our deep‑dive series on monoclonal antibody manufacturing. In Step 6, we performed low pH viral inactivation on the Protein A eluate, then neutralized the pool to pH 5.0–6.0. The resulting material is >95% pure, but it still contains low levels of critical impurities:
Aggregates (dimers and higher order species)
Leached Protein A (from the capture resin)
Residual HCPs (host cell proteins)
Residual DNA
Potential viruses (non‑enveloped, not inactivated by low pH)
Now we enter the polishing chromatography phase – typically two orthogonal steps: Cation Exchange (CEX) followed by Anion Exchange (AEX) . Step 7 covers CEX, the workhorse for aggregate removal.
Let’s dive into the principles, step‑by‑step operation, critical parameters, and troubleshooting.
Overview: What Is Cation Exchange Chromatography?
Principle: CEX separates proteins based on their net positive charge. The resin contains negatively charged functional groups (e.g., sulfopropyl (SP), carboxymethyl (CM), or sulfonate (S)) that bind positively charged proteins. Impurities with different charge profiles are washed away, and the mAb is eluted by increasing salt concentration or pH.
Why CEX for mAb polishing?
Most IgG1 antibodies have a basic isoelectric point (pI) of 7.5–9.0.
At the typical load pH of 5.0–6.0, the mAb is positively charged (net charge +5 to +15).
Aggregates often have slightly different charge distribution and can be separated from monomers.
Leached Protein A (pI ~4.5–5.0) is negatively charged at pH 5.0–6.0 and flows through or binds weakly.
Operating modes:
| Mode | Description | Use Case |
|---|---|---|
| Bind‑elute | mAb binds to resin; impurities flow through; mAb eluted with salt gradient | Maximum purity, aggregate removal |
| Flow‑through | Impurities bind; mAb flows through (requires mAb pI >7.5 and pH >6.0) | Simpler, but less effective for aggregates |
For a standard mAb process, bind‑elute CEX is the dominant choice.
Step 7.1: Column Packing and Qualification
Similar to Protein A, the CEX column must be packed and qualified before use.
Resin selection:
| Resin | Functional Group | Matrix | Capacity (g/L) | Typical Flow Rate |
|---|---|---|---|---|
| Fractogel EMD SO₃⁻ (Merck) | Sulfonate | Polymer | 80–120 | 100–300 cm/h |
| Poros XS (Thermo) | Sulfopropyl | Polystyrene | 60–100 | 200–500 cm/h |
| Capto S ImpAct (Cytiva) | Sulfonate | Agarose | 80–150 | 150–300 cm/h |
| Eshmuno S (Merck) | Sulfonate | Polymer | 70–120 | 150–300 cm/h |
Column packing: Same principles as Step 5 (Protein A). Bed height typically 15–25 cm. HETP and asymmetry tests are required.
Sanitization and storage: 0.5–1.0 M NaOH (30 min), then store in 0.1 M NaOH or 20% ethanol.
Step 7.2: The CEX Cycle – Step by Step
A typical bind‑elute CEX run takes 2–4 hours and follows these steps.
Step 7.2.1: Conditioning (Pre‑equilibration)
Purpose: Remove storage solution and sanitizing agent.
Buffer: Water for injection (WFI) or 50 mM Tris, pH 7.0 (low salt)
Volume: 2–3 CV
Step 7.2.2: Equilibration
Purpose: Set the column to the correct pH and conductivity for binding.
Buffer: 20–50 mM sodium acetate or citrate, pH 5.0–5.5 (sometimes with 10–50 mM NaCl to moderate binding)
Volume: 5–10 CV (until pH and conductivity are stable)
Critical: Conductivity should be ≤5–8 mS/cm. Higher salt weakens binding.
Step 7.2.3: Load (Binding)
Purpose: Bind the mAb to the resin while impurities flow through.
Load conditions:
Load pH: Same as equilibration (5.0–5.5). If the viral inactivated pool is at pH 6.0, adjust with dilute acetic acid before loading.
Load conductivity: ≤5 mS/cm (dilute with WFI if needed).
Load density: 50–100 g mAb per liter of resin (typically 80% of dynamic binding capacity).
Flow rate: 100–300 cm/h (2–5 min residence time).
Monitoring: UV (A280) – the mAb binds, so the UV signal drops. Breakthrough occurs when resin nears saturation.
Step 7.2.4: Wash (Post‑Load)
Purpose: Remove loosely bound impurities (HCPs, DNA, leached Protein A).
Wash 1 (low salt): Equilibration buffer (5–10 CV) – removes unbound material.
Wash 2 (intermediate salt – optional): 5–10 CV of 20–50 mM acetate + 50–100 mM NaCl, pH 5.0–5.5. This elutes some weakly bound impurities without eluting the mAb.
Wash 3 (high pH – optional): Some processes use a pH step wash (e.g., 20 mM Tris, pH 7.0) to remove more HCPs before elution.
Step 7.2.5: Elution
Purpose: Release the mAb from the resin, typically using a linear salt gradient or step elution.
Gradient elution (preferred for aggregate separation):
Buffer A: 20–50 mM sodium acetate, pH 5.0–5.5 (low salt)
Buffer B: Buffer A + 0.5–1.0 M NaCl (high salt)
Gradient: 0–50% B over 10–20 CV (or 0–300 mM NaCl over 15 CV)
Flow rate: 100–200 cm/h
Step elution (simpler, less resolution):
Elute with 20–50 mM acetate + 150–300 mM NaCl, pH 5.0–5.5 (single step)
Peak collection: Collect based on UV (A280) threshold. The mAb elutes as a peak; aggregates (more hydrophobic or differently charged) often elute slightly earlier or later. By collecting a cut (e.g., start at 50% peak height, end at 10% on descending side), you exclude aggregates.
Typical eluate characteristics:
mAb concentration: 2–10 g/L (diluted relative to load)
Aggregate reduction: from 2–5% to <0.5–1%
HCP reduction: additional 10–100×
Leached Protein A: typically below detection
Step 7.2.6: Clean‑In‑Place (CIP)
Purpose: Remove tightly bound impurities and sanitize.
CIP protocol:
0.5–1.0 M NaOH, contact time 30–60 min
Followed by WFI wash until pH <8.0
Storage in 0.1 M NaOH or 20% ethanol
Frequency: After each cycle or daily.
Step 7.3: Critical Process Parameters (CPPs)
| Parameter | Typical Range | Impact on Purity and Yield |
|---|---|---|
| Load pH | 5.0–5.5 | Lower pH → stronger binding but may trap HCPs; higher pH → weaker binding, risk of breakthrough |
| Load conductivity | 2–8 mS/cm | Lower conductivity → stronger binding; higher → mAb may not bind |
| Load density (g/L resin) | 50–100 | Overloading causes aggregate carryover into eluate |
| Wash pH and salt | pH 5.0–5.5, 0–100 mM NaCl | Higher salt removes more HCPs but may elute some mAb |
| Elution gradient slope | 10–30 CV | Shallower gradient → better aggregate separation but longer run time |
| Elution pH | 5.0–5.5 (for salt elution) | pH affects selectivity; some processes use pH gradient instead of salt |
| Flow rate | 100–300 cm/h | Higher flow reduces resolution; lower increases run time |
Step 7.4: Equipment and Scale Considerations
Chromatography skid: Same as for Protein A (Step 5), but must be compatible with the higher salt concentrations used in elution (e.g., up to 1 M NaCl). Stainless steel or single‑use flow paths are fine.
Column hardware: Stainless steel or glass. Single‑use columns (e.g., Repligen OPUS) are increasingly used for polishing to avoid cleaning validation.
In‑line dilution: If the load conductivity is too high (e.g., >8 mS/cm), dilute with WFI or low‑salt buffer using a static mixer and a second pump. This is common when the viral inactivated pool has been neutralized with base.
Fraction collection: To achieve the purity needed for final drug substance, many processes collect the eluate in multiple fractions and pool only the center cut (excluding the front and tail where aggregates elute). Automated fractionation based on UV slope or timed collection is standard.
Step 7.5: Aggregate Removal – The Key Value of CEX
Aggregates are the primary concern after Protein A. They are more immunogenic and can cause adverse reactions. CEX is exceptionally good at separating monomers from aggregates.
Why aggregates behave differently:
Aggregates often have slightly different surface charge distributions.
Some aggregates are more hydrophobic and bind more strongly.
The larger size of aggregates may affect diffusion into resin pores (steric exclusion).
Optimization tips for aggregate removal:
Use a shallow salt gradient (e.g., 0–300 mM NaCl over 20 CV).
Consider a pH gradient instead of salt (e.g., pH 5.0 to 8.0) – less common but can be very effective.
Load at lower density (e.g., 50 g/L instead of 80 g/L) to improve resolution.
Collect a narrow cut – you may sacrifice 5–10% yield to achieve <0.5% aggregates.
Analytical method: Monitor fractions by SEC‑HPLC to determine which fractions meet the aggregate specification.
Step 7.6: Process Integration – From CEX to Next Step
The CEX eluate (now called CEX Pool) is typically:
At pH 5.0–5.5, with 150–300 mM NaCl
mAb concentration 2–10 g/L
Aggregate level <1% (often <0.5%)
HCP level reduced to <10 ppm (depending on later steps)
Hold conditions: 2–8°C for up to 24–48 hours before the next polishing step (Anion Exchange or Viral Filtration).
Optional intermediate concentration: Some processes use ultrafiltration/diafiltration (UF/DF) between CEX and AEX to adjust pH and conductivity for the next column. More commonly, the CEX eluate is directly conditioned (diluted or pH adjusted) for AEX.
Step 7.7: What Can Go Wrong? (Troubleshooting)
| Problem | Possible Cause | Remedy |
|---|---|---|
| mAb breakthrough during load | Load conductivity too high; load pH too high; resin overloaded | Dilute load; lower pH; reduce load density |
| Poor aggregate removal (high % in pool) | Gradient too steep; load density too high; cut too wide | Shallow gradient (20–30 CV); reduce load to 50 g/L; narrow the cut |
| Low recovery (<80%) | Elution conditions too weak (low salt); mAb precipitated on column | Increase salt to 0.5–1.0 M; check pH; add excipients (e.g., 0.5 M arginine) |
| High HCP in eluate | Insufficient washing; load pH too low | Add intermediate wash (e.g., 50–100 mM NaCl); raise load pH to 5.5 |
| High backpressure | Resin fouled; filter clogged | CIP with NaOH; replace inlet frits; centrifuge or filter load before loading |
| Poor binding at pH 5.0 (mAb pI near 7.0) | mAb has lower pI than expected | Use a lower load pH (e.g., 4.5–5.0) or switch to a different resin (e.g., weak cation exchanger) |
Step 7.8: Alternatives and Emerging Approaches
Flow‑through CEX: If the mAb pI is very high (>8.5), you can run CEX in flow‑through mode where the mAb does not bind, but impurities bind. This is simpler but less effective for aggregates.
Mixed‑mode resins (e.g., Capto MMC): Combine cation exchange with hydrophobic interaction. Can be used as a single polishing step, replacing both CEX and HIC.
Continuous chromatography (e.g., twin‑column MCSGP): For high‑throughput polishing, but still rare in commercial mAb manufacturing.
For a legacy product like Humira, standard bind‑elute CEX remains the reliable choice.
What Comes Next?
The CEX pool, now low in aggregates and HCPs, moves to the final polishing step: Anion Exchange Chromatography (AEX) . AEX operates in flow‑through mode to remove DNA, endotoxins, and residual viruses. That will be Step 8: Anion Exchange Chromatography – Flow‑Through Polishing.
Questions for our readers:
What salt gradient do you use for aggregate removal on CEX?
Have you successfully replaced CEX with a mixed‑mode resin?
Share your experiences below. Next week: Step 8 – Anion Exchange Chromatography.
The text above is owned by the site above referred.
Here is only a small part of the article, for more please follow the link
Also see:


